The XC-9000 system is a completely electronic network PA system based upon the TCP/IP method. By leveraging the TCP/IP protocol, the system ensures the reliable and proper transmission of all information packages. Not just can it use existing local area network, such as LANs or the Net, to send broadcast signals, but likewise it can additionally be released on a devoted broadcasting network.


A single-server system can sustain up to 3000 terminals and enables for server cascading. There are no limitations on the simultaneous program networks, accomplishing true full electronic broadcasting.


System Features



Versatile PA System Design


The PA system design is simple, including service monitoring software program, network microphones, network amplifiers, network speakers, and other devices.All tools is linked through the TCP/IP intranet protocol, permitting versatile configuration and very easy administration of the system, with totally free control over broadcast web content, network gadgets, and areas through the network.


Ip Pa SystemIp Pa System
Comprehensive Sound Administration


The audio management software program includes integrated functions for creating program plans, versatile zoning, and pre-scheduled broadcasts.It supports 24-hour programs, enabling transforming settings throughout all day


Versatile Sound Source Assistance


The system supports numerous forms of audio resources for sending alerts like online speech and BGM playback. Sound sources can originate from digital music apps, CD/DVD players, microphones, and so on. In addition, the system gives diverse features of supporting numerous broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Fire Alarm System System Integration


The system has a fire alarm system feature and can be integrated right into a smoke alarm system. When the alarm main device receives the disconcerting signals, the wire will certainly transmit the signal to tools, which sets off the XC-9000, sending signals to audio speakers


Users can choose to predetermined setups to turn on full-area or zoned alarms in emergencies. The alarm system voices can be found in multiple types and might be modified providing to needs. Users can change language settings, upload and edit their audio sources according to precise demands, such as intruding alarm systems, fire alarm systems or air aid alarm systems, and so on.


Smoke Alarm System Integration


The system has a smoke alarm function and can be integrated into a smoke alarm system. When the alarm system main system obtains the startling signals, the cable will transmit the signal to tools, which triggers the XC-9000, sending signals to audio speakers


Customers can pick to pre-programmed setups to trigger full-area or zoned alarms in emergencies. The alarm voices come in numerous kinds and can be modified dealing with needs. Customers can alter language settings, upload and edit their audio sources according to specific needs, such as intruding alarms, fire alarms or air help alarm systems, etc.


App Control for System Procedures


The system makes it possible for mobile app login and usage, permitting customers to start broadcasts and various other procedures to accredited terminals with the server software program, making sure a structured and convenient experience.


Integrated SIP Compatibility


The system not just enables SIP phones to log in, yet likewise can be attached to third-party SIP web server or IPPBX, which establishes an entirely integrated and suitable communication system through smooth integration right into existing systems.


Open SDK


When big project like clever park occurs, the system provides an open SDK incorporated into third-party application systems - IP PA System


System Framework



Main Features


Scheduled Playback


The system has the ability to immediately relay according to the arranged jobs as long as users post the audio declare each amount of time of the day to the server and develop a playback schedule.


Area Broadcasting


The system can randomly divide a couple of network devices right into different areas to play specified audio programs or send statements to any kind of designated location. The quantity of each device can be from another location adjusted.


Real-time Broadcasting


The system can catch and relay radio programs or various other exterior audio sources in real-time, and at the same time broadcast them in sync.


Smoke Alarm Integration


The system can be integrated with the fire alarm system for control. When a smoke alarm signal is caused, it automatically triggers the emergency situation program function and supports surrounding floor alarms. It likewise enables hand-operated emergency situation broadcasting by clicking a single button.


SIP Phone Integration


The system can be integrated with SIP servers, Continued enabling online speech of voice broadcasting using SIP phones to send out news anytime and anywhere.


CCTV Integration


The digital devices such as IP POE Speakers adopts the worldwide typical ONVIF protocol, which enables their voices to be relayed by means of VMS systems. The terminals can additionally be incorporated with CCTV systems for integrated program.


Key Products



Sound Monitoring Software Program XC-9000


B/S style, sustains cross-platform applications.
Covers typical broadcasting system operates, permitting for dividers administration.
Unified administration of terminals within the system, checking out work status, and batch quantity change, and so on.
Supports structure multi-level server architectures, deploying monitoring according to customer geographical regions.
Offers SDK development plans for second advancement and combination with other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Intercom: Sustained, Integrated Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Surface Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Running Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Audio Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Regularity Reaction: 45Hz~ 18KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Regularity Action: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 60Hz~ 18KHz.
Operating Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Area Mixing Digital Amplifier NBS-2301


Power Supply : AC 220V, 50Hz.
Power : click over here 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Response :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP User Interface Unit NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Protocol: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm outcomes.
Running Temperature level: -10~ 50 ℃.
Dimensions: 483x259x44mm.


Service For College





Versatile Zoning Program:


The totally network terminals can recognize versatile zoning options, permitting broadcasting notices to private terminals or different areas ( gadgets).


Institution Bell System:


It offers school bell system at the beginning/ending of the course - SPON Communications. Numerous situations can be developed, including various arranged program jobs according to summer/winter timetable


Smoke Alarm Combination


It supports assimilation with emergency alarm systems, allowing emergency alarm signals to be integrated right into the PA system.


Classroom Sound Amplification


Terminals sustain day-to-day applications in classroom scenes. They can directory be connected to projectors or interactive white boards for audio boosting.


Ip Paging SystemIp Pa System

Smart Road Lamp/Security Pole



Assistance SIP Procedure:


Integrated SIP protocol for smooth integration with network interaction systems.


VMS Platforms Integration:


Integrated ONVIF method for combination with VMS systems.


Third-Party Combination:


Constructed In HTTP API for integration with third event platforms.


Voice Alarm Triggering:


Constructed in alarm system input interface for activating voice alarms with electronic cameras.


Option For Resort



Zone Control by Floor:


The system supplies full network setups, dividing zones counting on different floorings and control over each zone individually.


Smoke Alarm Assimilation:


The system can be integrated with smoke alarm system, enabling assimilation of smoke alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It supports programmable scheduled broadcasting, permitting versatile setups according to various requirements.


Emergency Broadcasting:


It sustains emergency broadcasting for the entire area, making it possible for one-click emergency situation communication.


Service For Manufacturing facility



Area Broadcasting:


It permits broadcasting to any type of zone, assuring no disturbance between different areas.


Alarm system Triggering:


Terminals have numerous kinds of user interfaces, enabling to set off alarms when attached with video cameras.


All Network Tools:


Implementation of totally network devices substantially lowers the trouble of operating such as checking devices on harmful sites, and therefore safeguarding people and residential or commercial property.


The implementation of all network devices significantly decreases the problem of operation and maintenance management


Integrated SIP Phones:


The system can be incorporated with SIP phone and program alerts utilizing SIP phones at any type of time and anywhere. Two-way audio talkback between SIP phones and IP POE Speakers makes it very easy for examining gadgets being in office or other offices.


The XC-9000 system is a totally electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system ensures the proper and reliable transmission of all data packages. The system supports various kinds of audio sources for sending alerts like online speech and BGM playback. In addition, the system gives varied functions of sustaining different broadcasting features such as set up broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page